Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
Add more filters










Database
Language
Publication year range
1.
JAMA Netw Open ; 5(8): e2228143, 2022 08 01.
Article in English | MEDLINE | ID: mdl-36001317

ABSTRACT

Importance: Variants of SARS-CoV-2 have sequence variations in the viral genome that may alter the accuracy of rapid diagnostic tests. Objective: To assess the analytical and clinical accuracy of 2 rapid diagnostic tests for detecting SARS-CoV-2 during 3 phases of variants. Design, Setting, and Participants: This diagnostic study included participants aged 18 years or older who reported onset of COVID-19-like symptoms within the prior 5 days and were tested at multiple COVID-19 testing locations in King County, Washington, from February 17, 2021, to January 11, 2022, during 3 distinct phases of SARS-CoV-2 infection (pre-Delta, Delta, and Omicron). Interventions: Two anterior nasal swab specimens were collected from each participant-1 for onsite testing by the SCoV-2 Ag Detect Rapid Self-Test and 1 for reverse transcriptase-polymerase chain reaction (RT-PCR) testing. Main Outcomes and Measures: The analytical limit of detection of the 2 rapid diagnostic tests (SCoV-2 Ag Detect Rapid Self-Test and BinaxNOW COVID-19 Ag Card) was assessed using Omicron (B.1.1.529/BA.1), Delta (B.1.617.2), and a wild-type (USA-WA1/2020) variant. Diagnostic sensitivity and specificity of clinical testing for the rapid antigen tests were compared with that of RT-PCR testing. Results: A total of 802 participants were enrolled (mean [SD] age, 37.3 [13.3] years; 467 [58.2%] female), 424 (52.9%) of whom had not received COVID-19 vaccination and presented a median of 2 days (IQR, 1-3 days) from symptom onset. Overall, no significant differences were found in the analytical limit of detection or clinical diagnostic accuracy of rapid antigen testing across SARS-CoV-2 variants. The estimated limit of detection for both rapid nucleocapsid antigen tests was at or below a 50% tissue culture infectious dose of 62.5, and the positive percent agreement of the SCoV-2 Ag Detect Rapid Self-Test ranged from 81.2% (95% CI, 69.5%-89.9%) to 90.7% (95% CI, 77.9%-97.4%) across the 3 phases of variants. The diagnostic sensitivity increased for nasal swabs with a lower cycle threshold by RT-PCR, which correlates with a higher viral load. Conclusions and Relevance: In this diagnostic study, analytical and clinical performance data demonstrated accuracy of 2 rapid antigen tests among adults with COVID-19 symptoms across 3 phases of SARS-CoV-2 variants. The findings suggest that home-based rapid antigen testing programs may be an important intervention to reduce global SARS-CoV-2 transmission.


Subject(s)
COVID-19 , SARS-CoV-2 , Adult , COVID-19/diagnosis , COVID-19 Testing , COVID-19 Vaccines , Female , Humans , Male , SARS-CoV-2/genetics
2.
Microbiol Spectr ; 10(4): e0076522, 2022 08 31.
Article in English | MEDLINE | ID: mdl-35924843

ABSTRACT

Burkholderia pseudomallei is the causative agent of melioidosis, a life-threatening disease common in Southeast Asia and northern Australia. Melioidosis often presents with nonspecific symptoms and has a fatality rate of upwards of 70% when left untreated. The gold standard for diagnosis is culturing B. pseudomallei from patient samples. Bacterial culture, however, can take up to 7 days, and its sensitivity is poor, at roughly 60%. The successful administration of appropriate antibiotics is reliant on rapid and accurate diagnosis. Hence, there is a genuine need for new diagnostics for this deadly pathogen. The Active Melioidosis Detect (AMD) lateral flow immunoassay (LFI) detects the capsular polysaccharide (CPS) of B. pseudomallei. The assay is designed for use on various clinical samples, including serum and urine; however, there are limited data to support which clinical matrices are the best candidates for detecting CPS. In this study, concentrations of CPS in paired serum and urine samples from melioidosis patients were determined using a quantitative antigen capture enzyme-linked immunosorbent assay. In parallel, samples were tested with the AMD LFI, and the results of the two immunoassays were compared. Additionally, centrifugal concentration was performed on a subset of urine samples to determine if this method may improve detection when CPS levels are initially low or undetectable. The results indicate that while CPS levels varied within the two matrices, there tended to be higher concentrations in urine. The AMD LFI detected CPS in 40.5% of urine samples, compared to 6.5% of serum samples, suggesting that urine is a preferable matrix for point-of-care diagnostic assays. IMPORTANCE Melioidosis is very challenging to diagnose. There is a clear need for a point-of-care assay for the detection of B. pseudomallei antigen directly from patient samples. The Active Melioidosis Detect lateral flow immunoassay detects the capsular polysaccharide (CPS) of B. pseudomallei and is designed for use on various clinical samples, including serum and urine. However, there are limited data regarding which clinical matrix is preferable for the detection of CPS. This study addresses this question by examining quantitative CPS levels in paired serum and urine samples and relating them to clinical parameters. Additionally, centrifugal concentration was performed on a subset of urine samples to determine whether this might enable the detection of CPS in samples in which it was initially present at low or undetectable levels. These results provide valuable insights into the detection of CPS in patients with melioidosis and suggest potential ways forward in the diagnosis and treatment of this challenging disease.


Subject(s)
Burkholderia pseudomallei , Melioidosis , Humans , Immunoassay/methods , Melioidosis/diagnosis , Melioidosis/microbiology , Polysaccharides , Sensitivity and Specificity
3.
mBio ; 13(3): e0093122, 2022 06 28.
Article in English | MEDLINE | ID: mdl-35546539

ABSTRACT

Inhalational anthrax is a fatal infectious disease. Rapid and effective treatment is critically dependent on early and accurate diagnosis. Blood culture followed by identification and confirmation may take days to provide clinically relevant information. In contrast, immunoassay for a shed antigen, the capsular polypeptide gamma-d-polyglutamate (γDPGA), can provide rapid results at the point of care. In this study, a lateral flow immunoassay for γDPGA was evaluated in a robust nonhuman primate model of inhalational anthrax. The results showed that the time to a positive result with the rapid test using either serum or blood as a clinical specimen was similar to the time after infection when a blood culture became positive. In vitro testing showed that the test was equally sensitive with cultures of the three major clades of Bacillus anthracis. Cultures from other Bacillus spp. that are known to produce γDPGA also produced positive results. The test was negative with human sera from 200 normal subjects and 45 subjects with culture-confirmed nonanthrax bacterial or fungal sepsis. Taken together, the results showed that immunoassay for γDPGA is an effective surrogate for blood culture in a relevant cynomolgus monkey model of inhalational anthrax. The test would be a valuable aid in early diagnosis of anthrax, which is critical for rapid intervention and a positive outcome. Use of the test could facilitate triage of patients with signs and symptoms of anthrax in a mass-exposure incident and in low-resource settings where laboratory resources are not readily available. IMPORTANCE Patient outcome in anthrax is critically dependent on early diagnosis followed by effective treatment. We describe a rapid lateral flow immunoassay that detects capsular antigen of Bacillus anthracis that is shed into blood during infection. The test was evaluated in a robust cynomolgus monkey model of inhalational anthrax. Rapid detection of capsular antigen is an effective surrogate for the time-consuming and laboratory-intensive diagnosis by blood culture, direct fluorescent antibody staining, or other molecular testing. The test can be performed at the point of patient contact, is rapid and inexpensive, and can be used by individuals with minimal training.


Subject(s)
Anthrax , Bacillus anthracis , Animals , Anthrax/diagnosis , Antigens, Bacterial , Humans , Immunoassay/methods , Macaca fascicularis , Respiratory Tract Infections
4.
Micromachines (Basel) ; 13(3)2022 Mar 20.
Article in English | MEDLINE | ID: mdl-35334778

ABSTRACT

To bring to bear the power of centrifugal microfluidics on vertical flow immunoassays, control of flow orthogonally through nanoporous membranes is essential. The on-disc approach described here leverages the rapid print-cut-laminate (PCL) disc fabrication and prototyping method to create a permanent seal between disc materials and embedded nanoporous membranes. Rotational forces drive fluid flow, replacing capillary action, and complex pneumatic pumping systems. Adjacent microfluidic features form a flow path that directs fluid orthogonally (vertically) through these embedded membranes during assay execution. This method for membrane incorporation circumvents the need for solvents (e.g., acetone) to create the membrane-disc bond and sidesteps issues related to undesirable bypass flow. In other recently published work, we described an orthogonal flow (OF) platform that exploited embedded membranes for automation of enzyme-linked immunosorbent assays (ELISAs). Here, we more fully characterize flow patterns and cellulosic membrane behavior within the centrifugal orthogonal flow (cOF) format. Specifically, high-speed videography studies demonstrate that sample volume, membrane pore size, and ionic composition of the sample matrix significantly impact membrane behavior, and consequently fluid drainage profiles, especially when cellulosic membranes are used. Finally, prototype discs are used to demonstrate proof-of-principle for sandwich-type antigen capture and immunodetection within the cOF system.

5.
PLoS Negl Trop Dis ; 16(3): e0010287, 2022 03.
Article in English | MEDLINE | ID: mdl-35320275

ABSTRACT

BACKGROUND: Yersinia pestis is the causative agent of plague, a zoonosis associated with small mammals. Plague is a severe disease, especially in the pneumonic and septicemic forms, where fatality rates approach 100% if left untreated. The bacterium is primarily transmitted via flea bite or through direct contact with an infected host. The 2017 plague outbreak in Madagascar resulted in more than 2,400 cases and was highlighted by an increased number of pneumonic infections. Standard diagnostics for plague include laboratory-based assays such as bacterial culture and serology, which are inadequate for administering immediate patient care for pneumonic and septicemic plague. PRINCIPAL FINDINGS: The goal of this study was to develop a sensitive rapid plague prototype that can detect all virulent strains of Y. pestis. Monoclonal antibodies (mAbs) were produced against two Y. pestis antigens, low-calcium response V (LcrV) and capsular fraction-1 (F1), and prototype lateral flow immunoassays (LFI) and enzyme-linked immunosorbent assays (ELISA) were constructed. The LFIs developed for the detection of LcrV and F1 had limits of detection (LOD) of roughly 1-2 ng/mL in surrogate clinical samples (antigens spiked into normal human sera). The optimized antigen-capture ELISAs produced LODs of 74 pg/mL for LcrV and 61 pg/mL for F1 when these antigens were spiked into buffer. A dual antigen LFI prototype comprised of two test lines was evaluated for the detection of both antigens in Y. pestis lysates. The dual format was also evaluated for specificity using a small panel of clinical near-neighbors and other Tier 1 bacterial Select Agents. CONCLUSIONS: LcrV is expressed by all virulent Y. pestis strains, but homologs produced by other Yersinia species can confound assay specificity. F1 is specific to Y. pestis but is not expressed by all virulent strains. Utilizing highly reactive mAbs, a dual-antigen detection (multiplexed) LFI was developed to capitalize on the diagnostic strengths of each target.


Subject(s)
Plague , Yersinia pestis , Animals , Antibodies, Bacterial , Antigens, Bacterial , Humans , Immunoassay/methods , Mammals , Plague/microbiology , Yersinia pestis/physiology , Zoonoses
6.
Pathogens ; 10(8)2021 Jul 22.
Article in English | MEDLINE | ID: mdl-34451388

ABSTRACT

Francisella tularensis is the causative agent of tularemia, a zoonotic bacterial infection that is often fatal if not diagnosed and treated promptly. Natural infection in humans is relatively rare, yet persistence in animal reservoirs, arthropod vectors, and water sources combined with a low level of clinical recognition make tularemia a serious potential threat to public health in endemic areas. F. tularensis has also garnered attention as a potential bioterror threat, as widespread dissemination could have devastating consequences on a population. A low infectious dose combined with a wide range of symptoms and a short incubation period makes timely diagnosis of tularemia difficult. Current diagnostic techniques include bacterial culture of patient samples, PCR and serological assays; however, these techniques are time consuming and require technical expertise that may not be available at the point of care. In the event of an outbreak or exposure a more efficient diagnostic platform is needed. The lipopolysaccharide (LPS) component of the bacterial outer leaflet has been identified previously by our group as a potential diagnostic target. For this study, a library of ten monoclonal antibodies specific to F. tularensis LPS were produced and confirmed to be reactive with LPS from type A and type B strains. Antibody pairs were tested in an antigen-capture enzyme-linked immunosorbent assay (ELISA) and lateral flow immunoassay format to select the most sensitive pairings. The antigen-capture ELISA was then used to detect and quantify LPS in serum samples from tularemia patients for the first time to determine the viability of this molecule as a diagnostic target. In parallel, prototype lateral flow immunoassays were developed, and reactivity was assessed, demonstrating the potential utility of this assay as a rapid point-of-care test for diagnosis of tularemia.

7.
PLoS Negl Trop Dis ; 14(11): e0008817, 2020 11.
Article in English | MEDLINE | ID: mdl-33141837

ABSTRACT

The 2013-2016 Ebola virus (EBOV) outbreak in West Africa and the ongoing cases in the Democratic Republic of the Congo have spurred development of a number of medical countermeasures, including rapid Ebola diagnostic tests. The likelihood of transmission increases as the disease progresses due to increasing viral load and potential for contact with others. Early diagnosis of EBOV is essential for halting spread of the disease. Polymerase chain reaction assays are the gold standard for diagnosing Ebola virus disease (EVD), however, they rely on infrastructure and trained personnel that are not available in most resource-limited settings. Rapid diagnostic tests that are capable of detecting virus with reliable sensitivity need to be made available for use in austere environments where laboratory testing is not feasible. The goal of this study was to produce candidate lateral flow immunoassay (LFI) prototypes specific to the EBOV glycoprotein and viral matrix protein, both targets known to be present during EVD. The LFI platform utilizes antibody-based technology to capture and detect targets and is well suited to the needs of EVD diagnosis as it can be performed at the point-of-care, requires no cold chain, provides results in less than twenty minutes and is low cost. Monoclonal antibodies were isolated, characterized and evaluated in the LFI platform. Top performing LFI prototypes were selected, further optimized and confirmed for sensitivity with cultured live EBOV and clinical samples from infected non-human primates. Comparison with a commercially available EBOV rapid diagnostic test that received emergency use approval demonstrates that the glycoprotein-specific LFI developed as a part of this study has improved sensitivity. The outcome of this work presents a diagnostic prototype with the potential to enable earlier diagnosis of EVD in clinical settings and provide healthcare workers with a vital tool for reducing the spread of disease during an outbreak.


Subject(s)
Antigens, Viral/immunology , Ebolavirus/immunology , Hemorrhagic Fever, Ebola/diagnosis , Immunoassay/methods , Viral Envelope Proteins/immunology , Viral Matrix Proteins/immunology , Animals , Antibodies, Monoclonal/immunology , Democratic Republic of the Congo/epidemiology , Diagnostic Tests, Routine , Disease Outbreaks , Enzyme-Linked Immunosorbent Assay , Female , Hemorrhagic Fever, Ebola/epidemiology , Humans , Immunologic Tests , Mice , Point-of-Care Systems , Point-of-Care Testing , Polymerase Chain Reaction
8.
mSphere ; 3(3)2018.
Article in English | MEDLINE | ID: mdl-29720523

ABSTRACT

Ascomycetes and zygomycetes account for the majority of (i) fungi responsible for cutaneous, subcutaneous, and invasive human fungal infections, (ii) plant fungal pathogens, (iii) fungi that threaten global biodiversity, (iv) fungal agents of agricultural spoilage, and (v) fungi in water-damaged buildings. Rapid recognition of fungal infection (or contamination) enables early treatment (or remediation). A bioinformatics search found homologues of Saccharomyces cerevisiae Mnn9p present in members of the Zygomycota and Ascomycota phyla and absent in members of the Chytridiomycota and Basidiomycota. Mnn9p is a component of the yeast mannan polymerization complex and is necessary for α-1,6 mannan production. A monoclonal antibody (2DA6) was produced that was reactive with purified mannans of Mucor, Rhizopus, Aspergillus, Fusarium, and Candida species. Experimentation using a 2DA6 antigen capture enzyme-linked immunosorbent assay (ELISA) and extracts of fungi from the four phyla found agreement between the presence or absence of Mnn9p homologues and production or lack of production of mannan reactive with 2DA6. Studies of cell extracts from yeast mannan mutants identified α-1,6 mannan as the epitope recognized by 2DA6. To translate this finding into a point-of-use diagnostic, a 2DA6 lateral flow immunoassay was constructed that detected mannan in (i) extracts of dermatophytes and fungi that produce trauma-related infection and (ii) tissue from plants infected with Grosmannia clavigera or Sclerotium cepivorum These studies (i) revealed that the conservation of α-1,6-linked mannan in fungi of the Zygomycota and Ascomycota can be exploited as a broad diagnostic target and (ii) have provided a means to detect that target in an immunoassay platform that is well suited for clinic or field use.IMPORTANCE A key question asked when faced with an infection, an infestation, or environmental damage is whether it is a fungus. Identification of fungi as the cause of the problem can lead to remediation or treatment. Zygomycetes and ascomycetes account for the vast majority of fungal causes of human, animal, and plant disease, large-scale biodiversity loss, agricultural spoilage, and contamination of water-damaged buildings. These studies revealed the conservation of a common cell wall structural component of zygomycetes and ascomycetes to be a diagnostic target applicable to multiple pathogenic fungi and have leveraged that insight for practical use. Monoclonal antibodies reactive with this pan-fungal structure were produced and used to construct immunoassays (including ELISA and lateral flow assay) for detection of a broad range of pathogenic fungi.


Subject(s)
Antibodies, Fungal/immunology , Ascomycota/isolation & purification , Mannans/immunology , Mucorales/isolation & purification , Mycoses/diagnosis , Plant Diseases/microbiology , Serologic Tests/methods , Antibodies, Fungal/isolation & purification , Antibodies, Monoclonal/immunology , Antibodies, Monoclonal/isolation & purification , Antigens, Fungal/immunology , Ascomycota/immunology , Enzyme-Linked Immunosorbent Assay/methods , Humans , Mucorales/immunology , Plants
SELECTION OF CITATIONS
SEARCH DETAIL
...